Water Pump Relay Controller Circuit Schematic
Water reservoir automatic level control
Simple circuitry – 12V supply
Device purpose:
By means of a Relay, employed to drive a water pump, this circuit provides automatic level control of a water reservoir or well.
Circuit operation:
The shorter steel rod is the “water high” sensor, whereas the longer is the “water low” sensor. When the water level is below both sensors, IC1C output (pin #10) is low; if the water becomes in contact with the longer sensor the output remains low until the shorter sensor is reached. At this point IC1C output goes high, Q1 conducts, the Relay is energized and the pump starts operating.
Now, the water level begins to decrease and the shorter sensor will be no longer in contact with the water, but IC1C output will be hold high by the signal return to pin #5 of IC1B, so the pump will continue its operation. But when the water level falls below the longer sensor, IC1C output goes low and the pump will stop.
SW1 is optional and was added to provide reverse operation. Switching SW1 in order to connect R3 to pin #11 of IC1D, the pump will operate when the reservoir is nearly empty and will stop when the reservoir is full. In this case, the pump will be used to fill the reservoir and not to empty it as in the default operating mode.
Parts:
R1,R2___________15K 1/4W Resistors
R3______________10K 1/4W Resistor
R4_______________1K 1/4W Resistor
D1______________LED any type and color
D2___________1N4148 75V 150mA Diode
IC1____________4001 Quad 2 Input NOR Gate CMos IC
Q1____________BC337 45V 800mA NPN Transistor
SW1____________SPDT Toggle or Slide Switch (Optional)
RL1___________Relay with SPDT 2A @ 230V switch
Coil Voltage 12V – Coil resistance 200-300 Ohm
Two steel rods of appropriate length
Read more source: http://www.redcircuits.com/Page129.htm
Related Links
more about Motor relay circuit
More about Relay driver circuit
More about Water control
Water Sensor Alarm Kit
Water Level Alarm by 4011
Pump Controller For Solar Hot Water System
Water Drain Pump Controller by IC 4013
Related Posts :
A hole needs to be digged at the lowest place in the celler that have water incomming problems. The hole is about 0.5 x 0.5 x 0.5 meter, at the bottom a large water pump is mounted. Then the different water levels was measured, so we know how to make the sensors. Read more original sourc ...
This circuit optimises the operation of a solar hot water system. When the water in the solar collector is hotter than the storage tank, the pump runs. The circuit comprises two LM335Z temperature sensors, a comparator and Mosfet. Sensor 1 connects to the solar collector panel while Sensor 2 ...
This be Water Sensor Alarm Circuit for warn the water level , by when sensor point touch the water. The circuit have a voice loud warn hear immediately. By this circuit uses the integrated circuit LM380 , usual use be power amplifier IC the small-sized , seek buy easy , be usable not difficult. ...
This circuit gives out an alarm when its sensor is wetted by water. A 555 astable multivibrator is used here which gives a tone of about 1kHz upon detecting water. The sensor when wetted by water completes the circuit and makes the 555 oscillate at about 1kHz. The sensor is also shown in th ...
Circuit Water Alarm with LM380 This be Rain alarm or Water Alarm circuit ,model to be simple. When sensor point touch the water. It is make the circuit works to have a voice warn hear. By the circuit composes the equipment is important be integrated number circuit LM380. It usual perform a ...







or