The MOSFET input of the CA3140 makes it ideally suited for use in a high impedance DC voltmeter. Switch S1 is the range selector. The input impedance is limited to 10M by the resistors used in the voltage divider, but this is still a very acceptable value. Before switching on for the first time, the mechanical zero adjustment of the 100m A instrument should be set so that the pointer rests just below zero on the scale. The unit is then switched on and with the input shorted, TR1 is adjusted until an exact zero indication is obtained. The TR2 is used for calibrating the meter so that the full scale deflection in the three ranges is 1V, 10V and 100V. The supply voltage can be anything between 8 and 20V. The current consumption is less than 6mA at 12V. The accuracy of this voltmeter depends mainly on the quality of the 100mA instrument and the care with which the unit has been calibrated.
|
Part List |
| R1=8.2Mohms | R7=1Kohms | C2-3=10uF 25V |
| R2-3=820Kohms | R9-10=10Kohms | D1=1N4148 |
| R4=82Kohms | TR1=10Kohms trimmer | IC1= CA3130 |
| R5=100Kohms | TR2=25Kohms trimmer | VV1=100uA instrument |
| R6-8=47Kohms | C1=1.5uF 25V |
Source ::http://users.otenet.gr/~athsam/dc_voltmeter.htm
Related Links
More circuit about Volt Meter
More circuit by IC CA3130
More circuit by IC CA3140
Circuit basic dot-bar Display for LM3914
Digital Measurements Temperature by LM335
Optical Power Meter by IC 741
Digital Step-Km Counter with IC 4026,4024
Test Transistor in Circuit by IC 4011
High impedance DC Voltmeter by IC CA3130
Light Sensitive Switch with LDR + 2N2926
Peak Level Indicator by IC LM723
AC Line testing circuit.
Car Temperature Gauge by IC CA3162 + CA3161
This entry was posted on Saturday, June 2nd, 2007 at 12:22 pm and is filed under Circuit diagram, meter.